Automation and integrated solutions Aquametro PadPuls M1, PW-250, etc.

The WebLog 250 data logger is a multifunctional digital M-Bus data logger for 250 devices with a touch screen and a Web server. Ports - USB, Ethernet, 2x RS-232 (C), RS-485. Built-in power supply 110 ... 250 V AC. The transfer rate is from 300 to 38,400 baud.
PW 3/20/60 level converters are used to connect devices on the M-Bus to a PC. The interfaces are RS-232, RS-485 and optoelectronic. The transfer rate is from 300 to 9600 baud. Protection type IP40. Powered by an external unit of 12 -24 V DC or AC. Operating temperature from 0 °C to + 55 °C. Mounting on a DIN rail or on a wall.
PadPuls M1, PadPuls M1C, PadPuls M2, PadPuls M2C, PadPuls M4C are pulse converters/adapters for connecting devices with pulse output and converting the output signal into an M-Bus bus.
PadIn 4 is a 4-channel analog converter for converting output signals to an M-Bus bus.
M-Bus level converter PW-250 is a converter for 250 devices with an intelligent control interface, and control 1000 devices. Interfaces - USB, Ethernet, 2 x RS-232 (C), RS-485. Power supply - 230 V AC. The transfer rate is from 300 to 38,400 baud. Protection type IP52. Operating temperature from 0 °C to + 45 °C. Memory - 1 GB.
PW001G - M-Bus is an RS-232C level converter for connecting to a PC as Slaves M-Bus.
TCP001 is a converter with driver software, connecting cable and RS-232 cable for M-Bus. Power supply: DC12V (AC adapter included). Operating temperature: 0 °C to +55 °C.
M-Bus Splitter - The splitter (divider) allows you to connect up to 4 M-Bus devices (counters). It makes it possible to connect two or M-Bus level converters, or two Master, and read information from devices connected to the splitter. Improves the quality and speed of the connection. Power supply: 24-35 V AC or 30-40 V DC. Data transfer rate: from 300 to 2400 baud.
The slave level converter converts PC signals from the RS-232C interface to the M-Bus bus and vice versa. Power supply: from RS232 or an external 5-30 V DC power supply. Data transfer rate: from 300 to 3900 baud. Operating temperature: 0 °C to +55 °C. The type of protection is IP20.
KV001A is a 2-pulse So converter and a stand-in. Power supply - 210-250 V AC. Operating temperature: 0 °C to +50 °C.
Mounting: on a wall or DIN rail.
AMBUS NET, AMBUS LINK, AMBUS ZS - Modern data reading and storage system.
The computer M-Bus modem is designed to transfer data from remote objects of the M-Bus network via an analog telephone line to a PC. It works in conjunction with an M-Bus modem for a level converter from RS232C to M-Bus. It can be used as a fax modem.
The LCS-8560C analog modem for a PC or data logger allows, in combination with a second modem on the opposite side, to organize data transmission between the PC and the data logger via an analog telephone line.
Analog-to-digital converter AnDi for converting output signals to M-Bus bus. Modular design – for 1, 2, 3 and 4 channels.
The equipment for filling railway and automobile tanks with chlorine solution consists of an electronic metering device Fluidwell F124, a flow recorder Fluidwell N413 with a full-fledged numeric keypad and a portable miniature printer with a receipt printing function.
All Aquametro products
About Aquametro
-
accuracy
Aquametro meters, like Swiss watches, have the same first-class build quality, high measurement accuracy, as well as a wide model range that allows you to meet any customer needs. -
application
Aquametro devices have all the necessary qualities for use in ASDA, in mobile object monitoring systems and simply for daily monitoring of energy consumption by the consumer. -
relevance
The company constantly monitors the sales of its products, thereby constantly improving the range, introducing new models, and as a result: Aquametro products are the leader in the market of metering devices.
NEW TECHNOLOGIES GROUP
Contact us or your local dealer for more information on certifications, features, reviews, pricing, stock availability and delivery terms for Aquametro products.
Reply guaranteed within 8 business hours
- (727)345-47-04
- (3955)60-70-56
- (8182)63-90-72
- (8512)99-46-04
- (3852)73-04-60
- (4722)40-23-64
- (4162)22-76-07
- (4832)59-03-52
- (8352)28-53-07
- (351)202-03-61
- (8202)49-02-64
- (3022)38-34-83
- (395)279-98-46
- (4932)77-34-06
- (3412)26-03-58
- (4012)72-03-81
- (4842)92-23-67
- (843)206-01-48
- (3842)65-04-62
- (4212)92-98-04
- (8332)68-02-04
- (4966)23-41-49
- (4942)77-07-48
- (861)203-40-90
- (391)204-63-61
- (3522)50-90-47
- (4712)77-13-04
- (4742)52-20-81
- (3519)55-03-13
- (375)257-127-884
- (495)268-04-70
- (8152)59-64-93
- (8552)20-53-41
- (831)429-08-12
- (3843)20-46-81
- (383)227-86-73
- (3496)41-32-12
- (3812)21-46-40
- (4862)44-53-42
- (3532)37-68-04
- (8412)22-31-16
- (342)205-81-47
- (8142)55-98-37
- (8112)59-10-37
- (863)308-18-15
- (4912)46-61-64
- (812)309-46-40
- (846)206-03-16
- (8342)22-96-24
- (845)249-38-78
- (8692)22-31-93
- (3652)67-13-56
- (4812)29-41-54
- (862)225-72-31
- (8652)20-65-13
- (3462)77-98-35
- (8212)25-95-17
- (4752)50-40-97
- (998)71-205-18-59
- (8482)63-91-07
- (3822)98-41-53
- (4872)33-79-87
- (4822)63-31-35
- (3452)66-21-18
- (347)229-48-12
- (3012)59-97-51
- (8422)24-23-59
- (8672)28-90-48
- (4922)49-43-18
- (423)249-28-31
- (844)278-03-48
- (8172)26-41-59
- (473)204-51-73
- (4112)23-90-97
- (4852)69-52-93
- (343)384-55-89